Routing Software 06-02 (OS3) Installation Guide
2S-9181-31X
automatic restart. If the connection is broken, the ppupdate command does not
terminate to fail in updating, and restoration of the GR2000 may be disabled.
10.If a message ",QYDOLGFRQWHQWVRI 83'$7(WJ]" is displayed while executing
ppupdate command, follow the instructions below:
Transfer the update file again to the user’s home directory, then execute
command cmp ~/UPDATE.tgz /primaryMC/usr/var/update/UPDATE.tgz to compare
files.
If the command completes without displaying any messages, execute the
ppupdate command again.
If some error messages are displayed before the cmp command completes,
execute cp ~/UPDATE.tgz /primaryMC/usr/var/update/UPDATE.tgz and then execute
the ppupdate command again.
2 Updating Software
The update procedure varies with the configuration of the GR2000 in current use.
Use the files listed in Table 2-1 to update the software. In addition, check the
configuration of the RM and MC card, and then update software by a procedure
suitable for the configuration in Table 2-2.
Table 2-3 shows versions which can be updated from and free MC space required for
updating. Note tha t 1K is equal to 1024 bytes.
Table 2-1 Files Required for Updating
No. Directory in CD-ROM File Name
1 All BA62.tgz
Table 2-2 Device Configuration, Version of Routing Software, and Update Procedure
No. Device Configuration Update Procedure
1 One RM in the router and two MCs in use Update procedure 1
2 One RM in the router and one MC in use Update procedure 2
3 Two RMs in the router and two MCs in use for each RM Update procedure 3
4 Two RMs in the router and one MC in use for each RM Update procedure 4
Table 2-3 Free MC Space Required for Updating
No. Earlier Version MC Capacity Updating Boot ROM
1 03-00-F 8562K Bytes Executed
2 03-03-/A 6649K Bytes Executed
3 03-03-/D 6640K Bytes Executed
4 04-01 5552K Bytes Executed
5 04-01-/D 5477K Bytes None