©Elation Professional®                             14                            impression™ 
Clamp Mounting (Hanging) 
The Impression™ provides a unique mounting assembly that integrates the base  as well as 
the safety  cable rigging point  in one  unit (see  the illustration  below). When mounting  this 
fixture to truss, be sure to secure an appropriately rated coupler  directly to the base using a 
M10 x 16mm bolt fitted through the center hole of the base. As an added safety measure be 
sure to attach  at least one properly  rated safety cable  to the fixture  using the safety cable 
rigging point integrated in the base.   
Floor Mounting 
The Impression ships  with a floor stand  that will properly  balance the fixture in  an up-right 
position. For upright operation always  use the dedicated floor stand mounted  to the bottom 
of the fixture, this will allow for additional bracing during upright operation. The floor stand is 
kept  securely attached  with  a  Camlock  quick-release system.  To attach  the  floor  stand 
properly, line up the Camlock fasteners with Camlock mounting points on the base  and turn 
the two fasteners 90° to lock them in place. To release the Camlock repeat the  same action 
in reverse. See the illustration on the next page for details on the floor stand.