©Elation Professional®                             24                            impression™ 
After switching ON the system the LEDs will be operated with a Pulse Width 
Modulation   
  (PWM) of 1200Hz.    
In addition all standard setting will be loaded (DMX start address [001], Normal Mode 
with 14 DMX channels).    
b)    600Hz Mode (Hold down the DOWN- button during power ON)    
After switching ON the system the LEDs will be operated with a Pulse Width 
Modulation   
  (PWM) of 600Hz.    
In addition all standard setting will be loaded (DMX start address [001], Normal Mode 
with 14 DMX channels).   
c)    Standard Mode (Hold down the ENTER- button during power ON)     
After switching ON the system the DMX start address will be set to [001]. All other 
setting remain unchanged.    
Additional Display Indication:   
As a default you'll find the following additional information in the first row of the LCD display:    
XX/X/XX   
  06 = 600Hz / 12 = 1200Hz  
  N = Normal Mode / C = Compressed Mode / H = High Res. Mode  
  N = Tilt normal / I = Tilt inverted    
  N = Pan normal   / I = Pan inverted