Elation Lighting www.elationlighting.com 25
lamp screws. The lamp filler neck must not in the direction lamp or lenses.
Attention: Use only the original lamp type!
6. Pull the lamp holder safely back in the shaft and close the four screws.
7. The running time of the lamp LA1 can be reseed in the Time Menu.
6 6 Maintenance and Cleaning the POWER WPOWER WASH 575EASH 575E
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-
fluid residues must not built up on or within the fixture. Otherwise the fixture's light-
output will be significantly reduced. Regular cleaning will not only ensure the
maximum light-output, but will also allow the fixture to function reliable throughout its
life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-
mended, under no circumstances should alcohol or solvents be used!
The inside optical system should be maintained only by authorized persons. Please
contact your local dealer.
6.1 Safety Regulations
Pull out the main plug!
Wait min. 20 minutes after the last operation to cool down the fixture.
Before you put the POWER WASH 575E
POWER WASH 575E into operation close the casing,
otherwise your retina can be hurt!
6.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Therefore
no general guidelines can be given. From this it follows that the intervals are only
suggestions from our practice experience.
Position
Interval
In this way
Outside optic
weekly
soft cloth and glass cleaning fluid
Color filter
monthly
soft cloth and glass cleaning fluid
Beam shape
monthly
soft cloth and glass cleaning fluid
Dimmer/Shutter
yearly
vacuum cleaner, airbrush, etc.
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Reflector
never
Lamp
never