Water inlet (cold water connection only)
Connect the hose to
a tap with a 3/4”
thread.
Installation should
comply with local
water authority and
building regulations’
requirements.
Set the hose correctly
by loosening the ring nut. After positioning the inlet hose, be sure to
tighten the ring nut again to prevent leaks.
Do not connect to a hot water supply.
The inlet hose is provided with a water stop
device, which protects against damage caused
by water leaks in the hose which could develop
due to natural ageing of the hose. This fault is
shown by a red sector in the window “A”.
Should this occur, turn the water tap off and
refer to your Service Force Centre to replace
the hose.
Water drainage
The appliance drain hose should hook into a standpipe, the hook in the
drain hose is formed using the plastic “U-Piece” supplied. The standpipe
should have an internal diameter of approximately 38 mm (see dia-
gram) thus ensuring there is an air break between the drain hose and
standpipe.
When discharging into a stand-
pipe ensure that the top of the
curve in the hose end is no
more than 90 cm (35.4”) and
no less than 60 cm (23.6”)
above floor level.
The upright standpipe should have a minimum
length of 30 cm (12”) from the bottom of the
elbow to the top of the pipe (see diagram).
Make sure that it is designed in such a way that
the end of the drain hose cannot be covered
with water.
52
Installation
3 pin
Max. 90 cm.(35.4")
Min.60 cm.(23.6")
Min. 30 cm.(12")
38 mm.(1/ ") diameter
standpipe
1
2
A
132998930.qxd 6/22/01 2:57 AM Pagina 52 (Nero/Process Black pellicola)