5. Fix the round eyelet screws provided tightly into
the holes (1).
6. Fix bracket (S) to the fan assembly.
7. The hood is supplied in the recirculation mode,
with the recirculation grille (G) fitted over the outlet
in the top of the fan assembly ready for use.
8. Insert the 4.2x44.4mm screws to be used for
fixing the fan assembly into the rawl plugs and
tighten about two thirds. Lower the fan assembly
and chimney onto the fixing bracket (S). Ensuring
the screws locate into the fixing bracket, than
tighten the screws fully.

Installation with the air outlet turned

towards the wall:

1. Draw a vertical line on the wall from the centre of
the cooking appliance, using a spirit level and
marking pen. This is to ensure the correct vertical
alignment of the appliance.
2. Using the cardboard template provided mark the
hole positions (1) on the wall 100mm either side
of the vertical line ensuring they are level and
that the distance between the lowest point of the
hood and the cooking appliance beneath meet
the clearance requirements quoted in the
paragraph titled ‘Clearance Heights’.
3. Using the cardboard template mark the hole
positions (to be used for fixing the chimney)
30mm either side of the vertical line. The holes
must be drilled at a distance of (X) from the
horizontal line running through the centre of the
canopy fixing holes (1), which is calculated by
measuring the lenght of the chimney required for
the installation plus 15mm to equal (Z) as
illustrated opposite.
4. Using a 8mm masonry bit, drill the fixing holes
for the canopy and the fan assembly and insert
the rawl plugs provided ready for the fixing
screws.
INSTALLING INSTRUCTIONS
S
S07_11
S07_23

G

ø120
ø150
100 100 ø 8
7
Z
X
48
20
650
S07_05
21 1