INSTALLATION INSTRUCTIONS FOR FREESTANDING GAS RANGE
REMEMBER — DO NOT ALLOW SPILLS, FOOD,
CLEANING AGENTS OR ANY OTHER MATERIAL TO ENTER THE GAS ORIFICE HOLDER OPENING. Always keep the Burner Caps and Burner Heads in place whenever the surface burners are in use.
7. Electric Ignition Surface Burners
Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power.
a.To check for proper lighting, push in and turn a surface
burner knob counterclockwise to the (lite) position. You will hear the igniter sparking (See Fig. 1).
b.The surface burner should light when gas is available to the top burner. Purge air from supply lines by leaving
knob in the (lite) position until burner ignites. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines.
c.Visually check that burner has lit. Once the burner lights,
the control knob should be turned out of the (lite) position.
d.There are separate electrodes (igniters) for each burner. Try each knob separately until all burner valves have been checked.
Test to verify if “LO or LOW” setting should be adjusted (right front position ONLY):
a.Push in and turn knob to (lite) until burner ignites.
b.Push in and quickly turn knob to LOWEST POSITION.
c.If burner goes out, reset control to OFF.
d.Remove the burner control knob.
e.Use a
Test to verify if “LO or LOW” setting should be adjusted (all other positions):
a.Follow steps a thru d above.
b.Insert a
Fig. 1
8.Adjust the "LOW" Setting of Surface Burner Valve (Linear Flow Valves):
Inner burner flame adjustment screw
Fig. 2 | Outer burner flame |
adjustment screw |
All other surface burners
Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out.
Note: Air mixture adjustment is not required on surface burners.
Operation of Oven Burners & OvenAdjustments
9. Electric Ignition Burners
Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power.
The oven burner is equipped with an electric control system as well as an electric oven burner igniter. If your model is equipped with a
Fig. 3
7