10Installation
Connect ductwork |
| Install filters |
(DUCTED HOODS ONLY)
1.Use 6" round metal duct to connect the discharge collar on the hood to the ductwork above (Fig. 11).
2.Use duct tape to make all joints secure and air tight.
3.Remove the tape from the lower flue and set it in place on the hood (Fig. 11).
TAPE |
6” ROUND METAL |
DUCT |
FIG.11 |
(DUCTED AND NON-DUCTED HOODS)
1.To remove the GREASE filters, pull the metal latch tab outside and unlock the filter.
2.To install the GREASE filters, align rear filter tabs with slots in the hood. Depress the metal latch tab, push filter into position and release. Make sure filter is securely engaged after installation.
NOTE
Prior to use, remove protective film from the filter frame.
(NON-DUCTED HOODS ONLY)
1.To remove the CHARCOAL filter, push in on the front filter latch. Pull the filter down to disengage the rear filter tabs.
2.To install the CHARCOAL filter, align the rear filter tabs with slots in the hood. Push the filter up into place until the front latch snaps securely into the slot. Make sure the filter is securely engaged after assembly.
3.Install GREASE filters after charcoal filter is in- stalled.
GREASE FILTERS |
| TABS |
| |
LATCH | RECIRCULATION |
FILTER |