Operating Instructions

Notes for Test Institutes

Testing in accordance with EN 60704 must be carried out with the appliance fully loaded and using the test programme (see Programme Table).

Tests in accordance with EN 50242 must be carried out when the salt dispenser and rinse aid container have been filled with salt and rinse aid respectively and using the test programme (see Programme Table).

 

Full Load:

Half Load:

 

12 place settings

6 place settings incl. serving dishes,

 

incl. serving dishes

leaving alternate positions free

Detergent Dosing:

5g + 25g (Type B)

20g (Type B)

Rinse Aid Setting:

4 (Type III)

4 (Type III)

 

 

 

Sample loading arrangements:

Upper basket

Lower basket with cutlery basket

Cutlery basket

33

Page 33
Image 33
Electrolux 50740 manual Sample loading arrangements, Upper basket Lower basket with cutlery basket