Electrolux 69802 G manual Wiring diagram, Permanent Connection, Replacement of the cable

Models: 69802 G

1 24
Download 24 pages 5.04 Kb
Page 18
Image 18
Permanent Connection

Instructions for the Installer

Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3

mm.between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

Replacement of the cable

The connection of the voltage cable to the appliance's terminal block is of type "Y". This means that its replacement requires the specific equipment of a technician. In this case, only cable types H05RR-F, H05 V2V2-F (T90) or H05 BB-F must be used. The cable section must be suitable to the voltage and the working temperatu- re.

The yellow/green earth wire must be approximately 2 cm. longer than the phase wires.

Wiring diagram

1.TAPS IGNITOR SWITCHES

2.IGNITOR UNIT

3.LED POWER INDICATORS

18

Page 18
Image 18
Electrolux 69802 G manual Wiring diagram, Permanent Connection, Replacement of the cable