FITTING THE STABILITY BRACKET
It is recommended that if the appliance is to be instal led with a flexible supply pipe, a stability bracket (SK.4729.A)
is fitted, and is available from your supplier (see Im portant Safety Requirements, page 28). These instructions
should be read in conjunction with the leaflet packed with the stability bracket.
1. Place the appliance in its intended p osition and level appliance.
2. Mark off 300mm from the left hand side of the appliance as sho wn in dimension 'A' Fig.4a. This is the centre
line of the fixing bracket.
3. Draw a line from the front edge of the feet (see Fig.4a) and remove appliance from its position. Mark off
dimension 'B' (see Fig.4a) back from this line on the cen tre line of the bracket to locate the front edge of the
lower bracket. Fix lower bracket (with two fixing holes) to the floor then measure the height from floor level to
engagement edge on back of appliance, dimension 'C' of Fig. 4 b.
4. Assemble upper bracket to lower bracket so that the underside of bracket is dimension 'C' + 3mm above floor
level. (See Fig. 4b)
Reposition appliance and check that top bracket engages into appliance back as shown in Fig. 4b.
INSTALLATION INSTRUCTIONS
(C)
100mm
487mm (B)
(
A
)
300mm
Fig.4a.
Fig.4b.