CONNECTING TO GAS SUPPLY
This appliance is designed to be installed with an a ppliance flexible connection only. Supply piping should not be
less than R3/8. Connection is made to the Rc ½ (½” B.S.P.) female threaded entr y pipe located just below the
hotplate level on the rear left hand side of the appliance. NOTE: ONLY LIQUID SEALANTS T O BE USED
WHEN INLET GAS PIPE IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT TAPE. Carry out a gas tightness test
after connecting to the gas supply. The gas bayonet connector must be fitted in the shaded area indicated in
Fg.3. Take into account that it must be possible to pull the app liance forward sufficiently. The hose must not get
caught on the stability bracket.
IMPORTANT: FLEXIBLE TUBING USED MUST COMPLY WITH BS.669 CURRENT EDIT ION.
LPG Flexible connections must be a type suitable for L.P.G and capable of operation up to 50 mbar and carry a
red stripe, band or label.
INSTALLATION INSTRUCTIONS
Fig. 3