GAS CONNECTIONS

GAS CONNECTIONS

Advice for safety

Before installation ensure that the local distribution conditions (gas type and pressure) and the pre-setting of the appliance are consistent.

This appliance must be installed only in a room with good ventilation.

This appliance must not connected to a chimney. It has to be installed and connected in accordance with the rules in force. Special attention should be paid to the applicable disposal concerning ventilation.

The adjacent furniture panels have to be heat proof or protected by such material.

The adjusting conditions of this appliance are mentioned on the rating plate.

Connection to gas supply.

Check that the gas flow and the diameter of the supply pipe is sufficient to supply all the appliances of the installation.

Check that all connections are tight.

Install an accessible and visible gas tap to isolate the appliance.

Gas connection

Gas connection must be carried out according to the rules in force.

Your cooker is delivered adjusted for the kind of gas stated on the rating plate.

Advice for safety The flexible rubber hose must not be run across the back of the appliance.

If it is necessary to run the pipework behind the cooker to reach the gas tap, rigid pipework should be used which conforms to current gas regulations.

Rigid Connection

Recommendations when using an appliance flexible connector are as follows:

-For NATURAL the gas installation pipes to the termination point shall comply with:

Specification for installation of low-pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas) – BS 6891;

connection of flexible hose

power

cord

rigid pipe

power

cord