Slide-In Cooktop/Downdraft Vent

Countertop Preparation

Countertop Preparation for 30" & 36" Slide-In Cooktop/Downdraft Vent Installation

 

 

 

Downdraft vent cutout opening

 

 

 

1/4" min.

 

 

in cooktop support platform

 

 

 

flat ledge

E

 

 

 

 

 

For detailed cooktop and

2 9/16"

7

1/2"

 

7

1 4

 

 

downdraft vent installation

 

 

 

 

 

/ "

 

 

 

 

 

 

 

specifications, refer to

 

C

 

 

 

 

 

model-specific product

D

 

 

 

 

 

page and installation

 

 

 

 

 

 

guide on web

 

 

 

B

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1"countertop

 

 

 

 

 

 

 

overhang

 

 

 

 

Vertical noncombustible surface - rear wall

 

 

 

 

 

 

 

 

 

 

1/4"min. flat ledge

2513/16"

 

 

 

 

 

 

 

 

 

Studwall

 

Downdraft

 

 

 

 

 

chimney top

Countertop*

E30DD75ESS/30" Cooktop Cutout Dimensions

 

 

 

 

 

30" Cooktop

A

B

C

D

E

E30GC74GPS*

29 15/16"

29 3/16"

22"

25 13/16"

27 3/4"

E36DD75ESS/36" Cooktop Cutout Dimensions

36" Cooktops

A

B

C

D

E

E36EC75DSS

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36EC75ESS

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36EC75HSS

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36GC75DSS*

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36GC75ESS*

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36GC75GSS*

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36GC76EPS*

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

E36GC76GPS*

35 15/16"

35 3/16"

22"

25 13/16"

33 3/4"

*Proper combination installation will require cooktop power cord to be relocated to underside of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation Instructions page.)

3"

 

 

 

9/32"

Vent unit

Slide-In Cooktop

115/16"

 

 

 

Stiffener

End of cooktop

Back side of

213/16"

support platform

cabinet front

Cooktop Installation Note:

To ensure proper installation, refer to model-specific installation guide on web for cooktop dimensions, cutout dimensions and cabinet requirements.

Countertop Preparation Note:

Countertop with backsplash may not allow enough flat area for proper installation, 2-13/16" of flat countertop required behind cooktop. No gap required between back of cooktop and front of downdraft trim piece.

*Standard 25" countertop depth is NOT adequate for slide-in cooktop / vent installations.

Slide-In Cooktop / Downdraft Vent

Countertop Preparation Specifications

For detailed Slide-In Cooktop installation, refer to model-specific product page and installation guide on web. Plan installation so that all required minimum clearances between cooktop, overhead cabinets and adjacent vertical walls are provided.

Position cooktop/vent cutout so all required minimum clearances are met.

Minimum flat countertop area must meet or exceed combined overall width and depth as shown. Standard 25" countertop depth is NOT adequate for slide-in cooktop/vent installations.

Separate circuits required for cooktop and vent. (Refer to product-specific electrical specifications.)

Always consult local and/or national electric and gas codes. Check local building codes for installation requirements, as they may vary per locale.

Proper combination installation will require 30" & 36" Gas Slide-In Cooktop power cord to be relocated to underside of unit. (For details, refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation Instructions on web.)

Downdraft Vent Specifications

For detailed Downdraft Vent installations, refer to model-specific product page and installation guide on web.

Voltage Rating – 120V/ 60Hz/15 Amps

Connected Load (kW Rating) @120 Volts = 1.0kW

(For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)

Amps @120 Volts = 8.0 Amps

Vent unit outside of building only.

Vent must be installed in vertical orientation only.

1,600 CFM remote exhaust blower (PN# 5304444802) included with vent – shipped in separate box.

Do not use flexible duct. Round duct instead of rectangular duct recommended, especially when elbows are required.

When multiple elbows are necessary, ensure a minimum of 24" of straight duct between any two elbows.

Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold.

For most efficient airflow exhaust, use a straight run or as few elbows as possible.

Cold weather installations should have additional backdraft damper installed.

Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency.

Downdraft Vents can NOT be used in combination with any cooktop backsplash.

Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions.

Electrolux Major Appliances, N.A.

USA 250 Bobby Jones Expressway Augusta, GA 30907 1-877-4electrolux (1-877-435-3287) electroluxicon.com

High standards of quality at Electrolux Home Products, Inc. mean we are

CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxicon.ca

constantly working to improve our products. We reserve the right to change

specifications or discontinue models without notice.

SIC_DDV_PREP 01/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

Page 3
Image 3
Electrolux E36EC75DSS Slide-In Cooktop/Downdraft Vent Countertop Preparation, E30DD75ESS/30 Cooktop Cutout Dimensions