Installation

Unpacking

Check that the cooker hood is not damaged. Transportation damages should immediately be reported to the company responsible for transportaion.

Damages, faults and any missing parts should immediately be reported to the retailer.

Take care of the packing materials so that small children cannot play with them.

Location

The hood is to be mounted on the wall.

When installed, the hood must be not less than 65 cm. above electric burners or 70 cm. above gas or mixed-fuel burners (fig. 7).

Electrical connection (not for

Fig. 7

 

UK)

 

Safety warnings for the electrician

 

Before connecting the appliance to the power

 

supply, check that the voltage indicated on the

 

rating plate corresponds to the mains power supply

 

available. Appliances fitted with a plug can be

 

connected to any standard power socket within

 

easy access.

 

Should it be necessary to provide a fixed

 

connection, the hood must only be installed by an

 

electrician authorised by the local electricity board.

 

When installing, a double pole switch with a

 

distance of at least 3 mm between contacts must

 

be provided.

 

Fixed connection of the appliance must only be

 

carried out by an authorised electrician.

38

Electrical connection for UK

only

Safety warnings for the electrician

Connect the hood to the mains supply via a double

pole switch which has 3 mm minimum separation

between the contacts.

The switch must be accessible at all times.

The following is valid in the United Kingdom only:

- the wire which is coloured blue must be

connected to the terminal which is marked with

the letter N or coloured black, -

- the wire which is coloured brown must be

connected to the terminal which is marked with

the letter L or coloured red.