Installation

Mounting accessories included

5wall dowels (brick fixing only)

5screws 5 x 45

6screws 3x9 (to fix suction unit to lower part of the hood and to fix the deflector)

2scrws 2,9 x 6,5 (to fix chimney)

1allen spanner (for TORX screws)

1support bracket

Wall mounting

First decide how the hood is going to be used, extraction or recirculation.

If you decide to use the hood in extraction version we suggest the upper section of the chimney is positioned so that the oulet slots are not visible once installation has ended. If, however, it is decided to use the hood in recycling version ENSURE that the side with slots is up (see also A-B-C sequence on Fig. 8).

Ensure that the hood is not connected to the mains supply during installation, remove the grease filter and the charcoal filter frame.

Attention!

If necessary, steps 1-2-3can be performed after step 16.

Rest the suction unit on a flat surface and thread the lower part of the hood onto it (1).

Make all the electrical connections between the two parts (2).

Fasten the hood to the suction unit using 4 screws (3).

Mark the wall with a centre line, this will aid mounting procedure (4), position the template so that the mid line printed on the template matches with the centre line previously marked, the lower side of the template corresponds to the lower side of the hood once mounted (5).

Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws (6).

Hang the hood (7) adjust its position (8-9)and from the inside of the hood sign one point for definitive fixing (10), remove the hood (11) and drill an hole Ø 8mm (12), fit a wall plugs (13).

Drill two holes Ø 8mm on the upper side close to the ceilling (14), fit two wall plugs and fix the chimney support with two screws (15).

Hang the hood again (16).

Fix it securely with a screw (17). To simplify the mounting operation remove the carbon filter frame.

In case the hood is to be used in filter version, mount the deflector F on the chimney support G with two screws and fit an exhaust pipe (18) to connect deflector to the outlet hole B of the hood.

In case the hood is to be used in exhausting version, then the deflector must not be mounted and fit an exhaust pipe (18) to connect outlet hole B of the hood to the outside.

Make electrical connection (19), but leave the hood disconnected from the home general electric panel.

Fix the chimney (20a) to the chimney support (20b).

Slide down the lower section on the proper housing on top of the hood. Refit the charcoal filter frame, the grease filter and connect the hood the the household mains supply and check that the hood works correctly.

12

Page 12
Image 12
Electrolux EFC 980 user manual Mounting accessories included, Wall mounting