11
Building In
ON/OFF SWITCH
FLEX
OUTLET
ON/OFF SWITCH
FLEX
OUTLET
FO 0763
FO 0764
1
2

Building over a cupboard or

drawer

If the hob is to be installed above a cupboard or drawer it
will be necessary to fit a heat resistant board below the
base of the hob on the underside of the work surface.
It is also recommended to carry out the electrical
connection to the hob as shown in diagrams 1 and 2.
Installation
The hob must be installed according to the
instructions supplied.
The hob must be installed by qualified personnel
to the relevant British Standards.
The manufacturer will not accept liability, should
the above instructions or any of the other safety
instructions incorporated in this book be ignored.
Please, ensure that, once the hob is installed, it
is easily accessible for the engineer in the event
of a breakdown.

When the hob is first installed

Once the hob has been installed, it is important
to remove any protective materials, which were
put on in the factory.

Supply Connections

This hob is designed to be connected to 230-240 V (50Hz)
electricity supply.
The hob has a terminal block which is marked as follows:
L - Live terminal
N - Neutral terminal
or E - Earth terminal
The cable used to connect the hob to the electrical supply
must be 6mm, PVC twin and earth, and fused to 30amp.
It is necessary that you install a double pole swith between
the hob and the electricity supply (mains), with a minimum
gap of 3mm between the swith contacts and of a type
suitable for the required load in compliance with the current
rules.
The swith must not break the yellow and green earth cable
at any point.
560
480
580
510
55 min.
FO 2230
Rectangular cut-out size for hob

Cut Out Size

The dimensions of the cut-out are given in the diagram.