Electrolux EHG 6402 Type Of Gas, Burner, Rapid, Position, Natural Gas, Power, mbar, Value =, Rate

Models: EHG 6832

1 36
Download 36 pages 52.22 Kb
Page 16
Image 16
BURNER

16 electrolux

BURNER

RAPID

SEMI-RAPID A U X I L I A R Y TRIPLECROWN

TYPE OF GAS

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

M A X

MIN

M A X

MIN

M A X

MIN

M A X

MIN

 

NOMINALTHERMAL

 

 

 

 

 

 

 

 

NATURAL GAS

POWER

kW

3.0

0.75

2.0

0.45

1.0

0.33

4.0

1.2

 

 

 

 

 

 

 

 

 

 

20 mbar

NOMINALFLOW

 

 

 

 

 

 

 

 

 

VALUE =

RATE

m3/h

0.286

0.057

0.190

0.038

0.095

0.028

0.381

0.114

37.78 MJ/m3

NOZZLEREFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

146

Adjust.

Ws - 50.7 MJ/ m3

1/100mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPG GAS

NOMINALTHERMAL

 

 

 

 

 

 

 

 

POWER

kW

2.8

0.75

2.0

0.45

1.0

0.33

4.0

1.2

28-30/37 mbar

NOMINALFLOW

 

 

 

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

 

 

 

RATE

g/h

202 43.5

144

29

72

21,5

291

86

49.92 MJ/Kg

 

NOZZLEREFERENCE

86

42

71

32

50

28

98

56

 

1/100mm

 

 

 

 

 

 

 

 

 