Installation instructions

Hints on safety

This appliance must be installed and connec- ted by a qualified electrician or competent person. Please observe this instruction, otherwise the warranty will not cover any da- mage which may occur.

During the installation and in case of a service fai- lure the appliance must not be connected to the mains.

The general rules for the operation of electric ap- pliances, the provisions by the competent electri- city supply board and the specifications of these instructions for installation have to be strictly ad- hered to.

Building into the kitchen worktop

Electrical safety is to be ensured by professional installation.

Protection against accidental contact according to the regulations set by VDE or other local autho- rities must be ensured by correct installation of the appliances. The same refers to the back of the appliance which, even in case of built--in installa- tions away from the wall, must not be freely accessible.

Built--in cupboards have to be located and faste- ned in a way that they are stable.

. Note down the data from the rating plate of your appliance in the printed rating plate form in this manual. These numbers are needed in case of service calls.

Installation dimensions

The opening in the cabinet must correspond to the standard dimensions. The necessary information can be found in the dimensional sketch.

. The separation between the lower surface of the hob and the parts of the furniture below it must be at least 20 mm

. The lateral separation between the sides of the hob and the cabinet must be at least 50 mm, and must be at least 55 mm from the rear panel.

With regard to the protection against overheating of surrounding furniture surfaces this appliance corresponds to type Y. This appliance or the built-- in cupboard for the appliance respectively may be located with the rear wall and one side wall to wha- tever high walls or furniture respectively and with the other side to another appliance or furniture of the same height as this appliance.

distance from worktop

opening to the rear wall

55 mm

20 mm

distance from worktop opening to the left or right side wall or to a high cupboard

50 mm

20 mm

R5

12