Electrical connections

Before connecting the appliance, check that the

voltage quoted on the rating plate - that is, the no- minal voltage of the appliance - corresponds to the available mains voltage. The rating plate can be found on the base of the ceramic glass hob.

. The mains connection must be carried out by an expert electrician. The VDE-regulations and the valid regulations by the electricity supply boards have to be compiled with.

. Prior to connection it should be checked whether the voltage stated on the rating plate -- i.e. the nominal voltage of the appliance -- is identical with the mains voltage. The rating plate is located on the base housing of the hob.

. The heating element voltage is to 230 V ~. The appliance will also perfectly perform with the lo- wer mains voltage of 220 V ~.

. The mains connection must be carried out in a way that an all--pole insulating device is existing with a contact opening of at least 3 mm, e.g. LS-- automatism, earth--leakage circuit--breaker or fuse.

. A wire of type H05VV-F or of higher rating is to be used as supply cable.

. The mains terminal is located in the bottom of the appliance under a plastic cover. It can be opened using a screwdriver (see picture).

. Subject to the existing mains voltage, the ap- pliance has to be connected as shown opposite. The links of the terminal block must be changed accordingly, if appropriate.

. The earth conductor is to be connected to termi-

nal . The earth conductor must be longer than live leads.

. The cable connections have to be connected as shown and the terminal screws be firmly tightened.

. Afterwards the supply cable has to be secured by the cable clamp and the cover must be fitted by firmly pressing down until it engages.

Prior to first use remove any existing labels and protective film from the ceramic glass plate or the frame of the hob.

After connecting the electrical supply, all cooking zones should be briefly switched on one after the other at their maximum power, in order to test whether they are operational.

Mains terminal

in the base of the hob

changing brid- ges of the ter- minal

strain relief device

Connecting possibilities

1

2

3

4

5

UK only

 

 

 

 

 

230 V ~

L1

 

 

N

 

1 L + N

 

 

 

 

1

2

3

4

5

400 V

 

 

 

 

 

2 N ~

L1

 

L2

N

 

2 L + N

 

 

 

1

2

3

4

5

400 V

 

 

 

 

 

3 N ~

L1

L2

L3

N

 

3 L + N

 

 

1

2

3

4

5

230 V

 

 

 

 

 

2 ~

L1

(L3)

L2

 

2 L

 

 

1

2

3

4

5

230 V

 

 

 

 

 

3 ~

 

 

 

 

 

3 L

L1

 

L2

L3

 

 

Read the installation instructions before con- necting the mains cable. Ensuring that the links are fitted correctly to the terminal block

14

Page 14
Image 14
Electrolux EHO 603 K manual Electrical connections, + N, Connecting possibilities UK only 230 V ~, 400