Installation Instructions

30 electrolux installation instructions

Installation Instructions

Safety instructions

Warning! This must be read!

The laws, ordinances, directives and standards in force in the country of use are to be followed (safety regulations, proper recycling in accordance with the regulations, etc.)

Installation may only be carried out by a qualified electrician.

The minimum distances to other appli- ances and units are to be observed. Anti-shock protection must be provided by the installation, for example drawers may only be installed with a protective floor directly underneath the appliance. The cut surfaces of the worktop are to be protected against moisture using a suitable sealant.

The sealant seals the appliance to the work top with no gap.

Avoid installing the appliance next to doors and under windows. Otherwise hot cookware may be knocked off the rings when doors and windows are opened.

zRisk of injury from electrical current.

The electrical mains terminal is live.

Make electrical mains terminal free of voltage.

Follow connection schematic.

Observe electrical safety rules.

Ensure anti-shock protection by in- stalling correctly.

The appliance must be connected to the electrical supply by a qualified electrician.

zRisk of injury from electrical current.

Loose and inappropriate plug and socket connections can make the terminal overheat.

Have the clamping connections cor- rectly installed by a qualified electri- cian.

Use strain relief clamp on cable.

In the event of single-phase or two- phase connection, the appropriate mains cable of type H05BB-F Tmax 90°C(or higher) must be used.

If this appliance’s mains cable is damaged, it must be replaced by a special cable (type H05BB-F Tmax 90°C; or higher). The latter is availa- ble from the Customer Care Depart- ment.

A device must be provided in the electri- cal installation which allows the appli- ance to be disconnected from the mains at all poles with a contact opening width of at least 3 mm.

Suitable isolation devices include line protecting cut-outs, fuses (screw type fuses are to be removed from the hold- er), earth leakage trips and contactors.

Sticking on the seal

Clean the worktop around the cut- out area.

Stick the single-sided adhesive seal- ing tape provided on the underside of the hob around the outside edge ensuring that it is not stretched. The two ends of the tape should join in the middle of one side. After trim- ming the tape (allow it to overlap by 2-3 mm), press the two ends togeth- er.