Electrolux EK 5741 manual Electrical connections, Supply Cable Specifications

Models: EK 5741

1 20
Download 20 pages 44.88 Kb
Page 19
Image 19
Electrical connections

Electrical connections

Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This cooker is designed to be connected to a 230-240V 50Hz AC electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the hob. A copy is attached on the back cover of this book.

The cooker is supplied without supply cord. A 3 core flexible supply cord must be fitted, in accordance with the specification given in the relevant tables.

Φ1) Loosen the two fixing screws securing the back protective screen of the cooker, then lift it up and remove it. This will expose the terminal block on the right bottom corner.

2)Loosen the two cable clamp screws and lift the top section of the clamp enough to allow the cable to be passed through.

3)Connect the red (live) wire to the terminal which is marked with the letter "L".

4)Connect the black (neutral) wire to the terminal which is marked with the letter "N".

5)After fitting a green or yellow/green sleeve over the bare copper wire (earth wire), connect the exposed end to the terminal

which is marked with the earth symbol Supply Cable Specifications or with the letter "E"coloured green and yellow.

NOTE:The earth wire should be about 2 cm. longer than the live and neutral wires.

6)Secure the cable by means of the clamp screws and refit the back protective screen.

The cooker should be connected to a double pole switch with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations. The switch should be sited within 2m of the hob and be easily accessible upon completion of the installation.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

Supply Cable Specifications

For Uk use only

Connection

Min. size

Cable / flexFuse

via

Cable/flex

type

• Cooker

3 x 6 mm2

H05 VV-F 30 A

Control

 

 

Circuit

 

 

For Europe use only

Min.size Cable/flex

Cable / flex type

Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

3x 2.5 mm2

H05 RR-F

30 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FO 2375

19