Electrolux EOB53000 user manual Electrical Connection

Models: EOB53000

1 60
Download 60 pages 51.23 Kb
Page 47
Image 47
Electrical Connection

Electrical Connection

The oven is designed to be connected to 230-240V~(50Hz) electricity supply.

The oven has an easily accessible termi- nal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

E- Earth terminal

This oven must be earthed!

The cable used to connect the oven to the electrical supply must

comply to the specifications given be- low.

electrical connection electrolux 47

For UK use only

Connec-

Min.

Cable/

 

size

 

tion

flex

Fuse

Cable/

via

type

 

flex

 

 

 

 

 

 

 

Cooker

2,5 mm2 PVC/PVC

min:

Control

 

twin and

15A

Circuit

 

earth

max:

 

 

 

20A

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a mini- mum gap of 3mm

between the switch contacts and of a type suitable for the required load in compliance with the current regulations. The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the ca- ble must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient tempera- ture.

Before the oven is connected, check that the main fuse and the domestic in- stallation can support the load; and that the power supply is properly earthed.

The manufacturer declines any re- sponsibility should these safety measures not be carried out.

Page 47
Image 47
Electrolux EOB53000 user manual Electrical Connection