Electrolux EOG 10000 user manual Instructions for the Installer, Connectingtotheelectricalsupply

Models: EOG 10000

1 36
Download 36 pages 42.6 Kb
Page 22
Image 22
Instructions for the Installer

22electrolux

Instructions for the Installer

Installation and connection must be done in compliance with the regulations in force. Any interventions must be carried out when the appliance is switched off. Only accredited engineers may work on the appliance.

The manufacturer disclaims any liability if the safety measures are not observed.

Connectingtotheelectricalsupply

Before connecting to the electrical supply, please make sure:

-The fuse and the domestic electrical installation must be designed for the max. load of the appliance (see rating plate).

-The domestic electrical installation must be equipped with a proper earth connection in accordance with the regulations in force.

-The socket or the multi-pole off switch must be easy to access after the appliance has been installed.

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow- green earth wire at any point. The earth wire should be 2 cm longer than the live and neutral wires.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more

Live wire

Neutral wire

Earth wire

(yellow-green) at least 2 cm longer