than 60°C above the ambient tempera- ture.

Before the oven is connected, check that the main fuse and the domestic installa- tion can support the load and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.

Terminal block

The oven is fitted with an easily accessible terminal block which is designed to operate with a single-phase power supply of 230 V.

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This oven must be earthed

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection

Min. size

Cable /

Fuse

via

Cable/flex

flex type

 

 

 

 

 

• 13 A socket

0.75 mm2

3 core

13 A

outlet

 

butyl

min.

• 13 A

 

insulated

 

spurbox

 

 

 

• Cooker

0.75 mm2

PVC/PVC

13 A

Control

 

twin and

 

Circuit

 

earth

 

 

 

 

 

For Europe use only

Min. size Cable/

Cable / flex type

Fuse

flex

 

 

 

 

 

0.75 mm2

H05 RR-F

13 A

 

 

 

Page 23
Image 23