Only gas comes out when

Incoming water pressure too high. Install a

opening

pressure-limiting device.

 

Capacity temporarily exceeded. Wait for ten

 

minutes.

The water dispenser lamp and

Leakage at the water connection. Internal

the yellow indicator lamp

leakage, please contact your local Electrolux

flashes

Service Force Centre.

Indicator lamp for the water

The filter has been totally utilised. Replace the

filter flashes.

filter.

The indicator lamp stays on

80 % of the filter capacity expended. Buy a

and shows yellow

new filter.

Delivery is interrupted after a

The maximum time of two minutes is

short time

attained. Continue with delivery.

If after above checks there is still a fault call your local Service Force Centre. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.

Please note that proof of purchase is required for in-guarantee service calls.

TECHNICAL SPECIFICATION

Model

ERES35800W/ERES35800X

Net capacity Refrigerator l

324

Energy consumption kWh/y

175

Dimension mm

 

Height

1800

Width

595

Depth

650

Permissible water pressure (to ensure reliable function).

The total flow in the system can vary, depending on local water conditions and/or water pressure.

Lowest permissible water

Consult your installer if water pressure is

pressure. 2,5 bar (250kPa)

less than 2,5 bar.

 

 

Highest permissible water

If water pressure exceeds 10 bar, then a

pressure 10 bar (1MPa)

reduction valve must be fitted (available

 

from your specialist shop).

 

 

18

Page 18
Image 18