BUILDING IN
Instructions for building-in the appliance
Dimensions of the recess
Height of housing | mm 880 |
Depth of housing | mm 550 |
Width of housing | mm 560 |
50
540
560
550 | 880 |
|
PR 32
1.It is necessary that the cabinet has a ventilation recess with the following dimensions:
Depth 50 mm Width 540 mm
|
| 2 |
50 mm | min. | 200 cm |
| ||
|
| min. |
|
| cm2 200 |
D526 |
|
|
For appropriate venting, follow indications in the figure.
A |
D022 |
D132
3.Press in the joint covers between the appliance and the kitchen furniture.
D |
C |
D727 |
4.Open the door and push the appliance against the side of kitchen furniture opposite to that of appliance hinges.
Fasten the appliance with 4 screws provided in the kit included with the appliance. Snap vent grille (C) and hinge cover (D) into position.
B
D013
5.Apply blanking covers (B) as indicated.
2.Push the appliance into the housing until stop strip
(A) touches the kitchen unit.
15