TECHNICAL DATA
EUF29400X EUF29405W
EUF29405X
EUF29405K
EUF29406W
EUF29406X
EUF29406K
EUF29412W
EUF29412X
Dimension
Height 1800 mm 1800 mm 1800 mm 1800 mm
Width 595 mm 595 mm 595 mm 595 mm
Depth 623 mm 623 mm 623 mm 623 mm
Rising Time 12 h 12 h 12 h 12 h
The technical information are situated in the
rating plate on the internal left side of the ap-
pliance and in the energy label.
INSTALLATION
Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the cli-
mate class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Location
To ensure best performance, if the appliance
is positioned below an overhanging wall unit,
the minimum distance between the top of the
cabinet and the wall unit must be at least 40
mm . Ideally, however, the appliance should
not be positioned below overhanging wall
units.
If the cabinet is placed in a corner and the
side with the hinges facing the wall, the dis-
tance between the wall and the cabinet must
be at least 150 mm to allow the door to open
enough so that the equipment can be re-
moved.
The ventilation space can be:
• directly above the appliance
• behind and above the top cupboard.
In this case, the space behind the top cup-
board must be at least 50 mm deep.
Electrical connection
Before plugging in, ensure that the voltage
and frequency shown on the rating plate cor-
respond to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact
for this purpose. If the domestic power sup-
ply socket is not earthed, connect the appli-
ance to a separate earth in compliance with
current regulations, consulting a qualified
electrician.
The manufacturer declines all responsibility if
the above safety precautions are not ob-
served.
electrolux 11