6. TROUBLE SHOOTING
C)ABNORMAL NOISE IN THE APPLIANCE
In case of any abnormal noise coming out from the appliance, try to locate the source of the noise. Generally it may come from the compressor compartment. In such cases,
1.Take out the plug of the appliance from socket and open the plastic grid of the compressor compartment (see page 5, actions 1 )
2.Examine if the mounting brackets of the compressor are in place and secure, and if the mounting bolts for the fan are tight. If required replace broken or lost brackets and tighten loose bolts (see page 6 & 7, fig. 4 & 6)
3.Check if any pipe or component has come out of its position and also touching others. !f so, rectify carefully.
4.Check if the appliance is level and firm on its base. If not, rectify.
5.Even after actions as above if it is observed that the noise is still present or it is coming from the inside of the compressor - Notify Refrigerator Technician.
7. SHUTTING DOWN
IF THE APPLIANCE IS TO BE
SHUT DOWN FOR
TRANSPORTATION ETC.
Disconnect the
Leave the lid open till the appliance is absolutely dry
Roll the power supply cord into a coil and bind and place it carefully to avoid damage
8. STORAGE OF VACCINE AND ICEPACKS IN APPLIANCE
FOR STORING VACCINES
1.Keep the packets containing the vaccines in neat rows,
2.Different vaccines should be kept separately to facilitate easy identification.
3.Keep about 2 cm space between rows for circulation of air.
4.Keep a separate thermometer among the vaccines to ascertain the actual vaccine temperature.
14