Mains plug is not plugged in or is loose.

Symptom

 

Possible Cause

 

Remedy

 

 

 

 

 

Appliance does not work no pilot light is illuminated.

Green light does not light up, yellow light lights up when frostmatic fuction is activa- ted, appliance is on.

Yellow light does not light up, when frostmatic fuction is activated, appliance is on.

Appliance cools too much.

The freezer temperature is not sufficient, red light lights up, temperature alarm sounds

Heavy build up of frost, possi- bly also on the door seal.

The compressor does not start immediately after changing the temperature setting.

Appliance is not switched on

Mains plug is not plugged in or is loose.

Fuse has blown or is defective.

Socket is defective.

Green light faulty.

Yellow light faulty.

Temperature is set too cold.

Temperature is not properly adjusted.

Door was open for an exten- ded period.

A large quantity of warm food was placed in the appliance within the last 24 hours.

The appliance is near a heat source.

Door seal is not air tight (pos- sibly after changing over the hinges).

This is normal, no error has occurred.

Switch on the appliance.

Insert mains plug.

Check fuse, replace if neces- sary.

Mains malfunctions are to be corrected by an electrician.

Please inform your local AEG Service Force Centre

Please inform your local AEG Service Force Centre

Press the temperature setting button to a warmer setting. Please look in the "Initial Start Up" section.

Open the door only as long as necessary.

Press the frostmatic switch

Please look in the "Installation location" section.

Carefully warm the leaking sections of the door seal with a hair dryer (not hotter than approx. 50 °C). At the same time shape the warmed door seal by hand until it sits cor- rectly.

The compressor starts after a period of time.

14

If, after carrying out the necessary checks there is still a fault with your appliance please contact your local AEG Service Force Centre.

In guarantee customers should ensure that the suggested checks have been made as the engineer will make a charge if the fault is not a mecha- nical or electrical breakdown.

Please note that proof of purchase is required for any in-guarantee service calls.