6.WATER CONNECTIONS
6.1DRINKING WATER CONNECTION
•Before connecting the appliance, flush the water pipes and fittings and clean out any dirt.
•The appliance is designed for connection to fixed lines.
•Metal installation pipes may not protrude more than 3.9“ (10 cm) from the floor or the wall.
•The maximum water pipe pressure must not exceed 87 psi (600 kPa).
•A mechanical filter, a shutoff valve and a
•In general, all national and local water regulations must be observed.
•The appliance is to be connected to the sanitation system in accordance with the valid installation connection plans and diagrams.
6.1.1
DMake corresponding openings in the base of the frame to lead the hoses through.
DRemove front panel (B) (see Chapter 3. on page 7).
DDismantle the storage space or hot cabinet if necessary.
DConnect the flexible hoses (5), with a G ½" inside thread, with or without fitting a stop valve, to the
6.1.2FITTING AGAINST A WALL
The water connections come up from the floor or out of the wall. For floor connection (see Chapter 6.1.1 on page 9).
DPull the flexible hoses (5) out of the open rear wall and con- nect to the
DPosition the appliance against the wall.
6.2WASTE WATER
The appliance outlet pipe must be taken through a sufficiently large waste water opening.
Note
Ensure accurate measurement of the waste water collecting point and the exact positioning of the appliance.