Electric
Supply voltage: 534070 | 208 V/3p/60Hz |
534071 208 V/3p/60Hz
534072 240 V/3p/60Hz
534073 240 V/3p/60Hz
Dishwasher has three selectable hot water booster configurations according to inlet water supply temperature.
Dishwasher requires two separate electrical service connections. Connection 1 for Hot Water Booster; Connection 2 for running of the machine (wash pump, tank heat, conveyor drive motor, rinse booster pump, electronic control). Refer to the information below for Amp requirements.
Booster 40 °F rise Electrical Characteristics
Hot Water Booster Amp Load Connection 1:
208 V/3p/60Hz | 33.35A (12 kW) |
240 V/3p/60Hz | 28.9A (12 kW) |
Wash Pump, Tank heat Amp Load Connection 2:
208 V/3p/60Hz | 61.7A (21 kW) |
240 V/3p/60Hz | 55A (21 kW) |
Total Amp Load: 208 V/3p/60Hz | 95A (33 kW) |
240 V/3p/60Hz | 83.9A (33 kW) |
Booster 70 °F rise Electrical Characteristics
Hot Water Booster Amp Load Connection 1:
208 V/3p/60Hz | 50A (18 kW) |
240 V/3p/60Hz | 43.3A (18 kW) |
Wash Pump, Tank heat Amp Load Connection 2:
208 V/3p/60Hz | 61.7A (21 kW) |
240 V/3p/60Hz | 55A (21 kW) |
Total Amp Load: 208 V/3p/60Hz | 111.6A (39 kW) |
240 V/3p/60Hz | 98.3A (39 kW) |
Booster 100 °F rise Electrical Characteristics
Hot Water Booster Amp Load Connection 1:
208 V/3p/60Hz | 66.6A (24 kW) |
240 V/3p/60Hz | 57.7A (24 kW) |
Wash Pump, Tank heat Amp Load Connection 2:
208 V/3p/60Hz | 61.7A (21 kW) |
240 V/3p/60Hz | 55A (21 kW) |
Total Amp Load: 208 V/3p/60Hz | 128.3A (45 kW) |
240 V/3p/60Hz | 112.7A (45 kW) |
Warewashing
44″ Single Tank Conveyor Dishwasher
with Built In Hot Water Booster WT44
Water
Inlet Water supply pressure: | 22 – 102 psi (150 – 700 kPa) |
Inlet Water supply temperature |
|
(booster size can be set on |
|
site during installation): | 140 °F (60 °C) |
| with booster set as 40 °F rise. |
| 110 °F (44 °C) |
| with booster set as 70 °F rise. |
| 80 °F (27 °C) |
| with booster set as 100 °F rise. |
Inlet Water supply hardness: | |
Incoming water line size: | G 3/4″ |
NOTE: Two Hot Water Inlets on machine can be fed by one incoming Hot Water line.
Drain line size: | G |
Water consumption: Gallons/hr: | 79.25 gal/hr (300 liters) |
Water consumption/rack: | 0.4 gal/rack (1.5 l/rack) |
Wash Temperature: | 160 – 172 °F |
Wash tank size: | 26 gal (100 liters) |
Wash pump power: | 2 hp (1.5 kW) |
Wash pump water flow: | 118.9 gal/min (450 l/min) |
Rinse Temperature: | 180 – 194 °F |
Rinse pump power: | 0.4 hp (0.32 kW) |
Rinse pump water flow: | 1.32 gal/min (5 l/min) |
Hot water booster capacity: | 6.2 gal (24 liters) |
Initial fill water requirements: | 32.2 gal (124 liters) |
Exhaust Requirements
Unit supplied as standard with extended vent hoods (can be removed during installation if not required). Exhaust extraction not more than 177 CFM (300 m³/h) Refer to installation diagram for minimum exhaust hood installation height .
Key Information
Productivity racks per hour | 200 racks / 3600 dishes |
(max speed): | (average 18 dishes per rack) |
Productivity racks per hour | 130 racks / 2340 dishes |
(min speed): | (average 18 dishes per rack) |
Table to Table connection: | 44″ (1118 mm) |
Number of Tanks: | 1 |
Height with door open: | |
Charging hole size (width): | |
Charging hole size (height): | |
Net weight: | 1012 lb (459 kg) |
Shipping weight: | 1210 lb (549 kg) |
Shipping width: | |
Shipping depth: | |
Shipping height: | |
Shipping volume: | 143 cu.ft (4.05 m3) |
Noise level: | <70 dBA |
Unit predisposed to accept external detergent dispensers, detergent probes and rinse aid dispensers.