ENGLISH

7

B4 TECHNICAL DATA

Standard cycle time may vary should the inlet water temperature be different from that indicated above.

MODEL WT65H WT65H
Supply voltage: 208 V, 1 ph, 60 Hz 39 amp 240 V, 1 ph, 60 Hz, 32 amp
Tota l Wa tts 13.6 kW 13.6 kW
Boiler heating elements 12.0 kW 12.0 kW
Tank heating elements 3.0 kW 3.0 kW
Water supply pressure 7.25 - 101 psi/50 - 700 kPa 7.25 - 101 psi/50 - 700k Pa
Water supply temperature 122°F/50°C 122°F/50°C
Water supply hardness for models without incorporated continuous water softner 140 ppm/14°fH max 140 ppm/14°fH max
Water supply hardness for models with incorporated continuous water softner 400 ppm/40°fH max 400 ppm/40°fH max
Rinse cycle water consumption 0,90 gallon/3.4 liters 0,90 gallon/3.4 liters
Boiler capacity 3 gallons/12 liters 3 gallons/12 liters
Tank capacity 11 gallons/42 liters 11 gallons/42 liters
Standard cycle time with water supply at 122°F/50°C 60/70/120 seconds 60/70/120 seconds
Legal noise level Leq <65 dB <65 dB
Minimum Supply - Circuit Ampacity 40 amp 33 amp
Net weight 282 lb/128 kg 282 lb/128 kg
Shipping weight 359.36 lb/163 kg 359.36 lb/163 kg
Shipping width 33 1/16” /840 mm 33 1/16” /840 mm
Shipping height 74 7/16” / 1890 mm 74 7/16” / 1890 mm
Shipping depth 36 5/8” / 930 mm 36 5/8” / 930 mm

Tabl e 1

WT65H208DU WT65H240DU WT65H208WS WT65H240WS

xx