Riser Visor Turbo Nozzle
Micron Filter (on certain models only)
Check the micron filter periodically and change as needed. For maximum efficiency, replace the micron filter twice a year.
To Replace Micron Filter
1.Push down on latch and pull out on Micron filter door to remove.
2.Grasp filter and pull out.
3.Place new Micron filter into cleaner.
4.To close, place micron filter door on top of bottom tab, pivot door up and press door against cleaner until it latches.
Use ELECTROLUX replacement filters ONLY.
HEPA Filter (on certain models only)
Check the HEPA filter periodically and change as needed. For maximum efficiency, replace the HEPA filter twice a year.
To Replace HEPA Filter
1.Push down on latch and pull out on HEPA filter door to remove.
2.Grasp filter and pull out.
3.Place new HEPA filter into cleaner.
4.To close, place HEPA filter door on top of bottom tab, pivot door up and press door against cleaner until it latches.
Riser Visor Turbo Nozzle
Maintenance Instructions
1.To open Turbo Nozzle, unscrew the
two (2) screws on the side (as pictured).
2. Lift up the bottom housing. | Screws |
|
3.Clear blockage from brushroll area.
4.To close, align top and bottom housings and tighten with the two (2) screws.
Latch
Micron
Filter
Door
Micron
Filter
Latch
HEPA
Filter
Door
HEPA
Filter
12
34
14