Congratulations and good fortune!

We congratulate you to your selection of Oxy3etage or ZCV750W Central vacuum cleaners from Electro- lux that will give you many years of enjoyment and good use. These units are built on current technology for central vacuum cleaners, an entirely new way of thinking. The units, with their modern design and compact construction are most easy to place. With their new electronics, the units can be connected to normal electrical sockets without slow fuses. Since you have been wise enough to choose a big and established brand, it means security in the way of modern design, quality, service and spare parts. Your new central vacuum cleaner is tested and approved according to the requirements of the authorities. Carefully read this manual before you use the vacuum cleaner.

Safety instructions

Read these instructions carefully before installing and using your central vacuum cleaner to ensure your full satisfaction with the unit.

The central vacuum cleaner is only designed for traditional cleaning. It is therefore forbidden to vacuum fluids, ashes and sharp items.

Never use the vacuum cleaner in spaces where there might be burning or easily combustible fluids or gases.

Always pull out the plug when servicing the unit.

When you pull out the plug, pull by the plug, never the flexible cord.

The main fuse must be 10Amps.

The central vacuum cleaner must not be installed in a li- mited space. The dimensions of the space must be (mm) 490x570x700 (WxDxH).

Never cover the central unit.

Follow the instructions carefully.

Servicing the central vacuum cleaner must only be carried out by an authorised servicing company. Always use spare parts and accessories that are recommended by the manufacturer. Never try to make any changes yourself to the central vacuum cleaner.

Never use the central vacuum cleaner with a damaged connec- tion cord.

The central vacuum cleaner has a special cord that must always be replaced with a similar one, which can be purchased at an authorised service company.

Never use the vacuum cleaner without a dust bag

Save this manual for future use.

Technical Specifications

Model

ZCV750W

Oxy3etage

Width mm

460

460

Height mm

330

440

Depth mm

220

310

Power supply V

230

230

Fuse Amp

10

10

Protection class

IP11

IP11

Engine

1-step TF

1-step TF

 

high-power

high-power

Capacity max W

1600 1

600

Capacity nominal W

1400

1400

Airflow max litres/second*

52

52

Vacuum max* Kpa

27

27

Suction capacity max* W

554

554

Suction capacity incl.

W 360

360

system

 

 

Dust collection %

Carpet 76,

Carpet 76,

 

Floor 99

Floor 99

Noise level at unit dB(A)

68

68

Bag size, litres

8

8

Net weight kilos

6,0

8,0

Filter

Washable

Washable

 

carbon filter

HEPA 12

Overheating protection

Yes

Yes

Colour

White

White

 

 

 

* measured at the unit

Recycling

We have chosen only high quality materials for this product. This product is not to be treated as household waste. It should be handed in for recycling. By ensuring that the product is handled in a correct manner, you will contribute to evade any negative environmental and health effects that may arise if the product is dispo-

sed of as household waste. For further information on recycling, you should contact your local authorities or the shop were you purchased this equipment.

Your connection with Electrolux

For questions about products, spare parts, maintenance, guaran- tees etc., please contact your local Electrolux company. You can find their address at www.electrolux.com

ZCV750W

Installing a wallboard for traditional mounting

We are assuming that for this type of installation, the pipes for inlet and outlet are hidden in the wall. Light built walls; the four screws of the wall plate are usually fixed on top of the boarding into the wooden elements of the wall. An extra beam is needed for the screws of one side. This is to be done before doubling the wall. To be able to get at the two connections on the wall plate, the boarding behind the plate is to be removed. Solid walls; the inlet and outlet pipes are mounted, and the wall is subsequently doubled. For porous concrete and brick walls, channels for the pipes are to be made. These channels are to be filled before surface treatment of the wall is carried out. Picture 1.

When installing the pipes, include a low-voltage cable for the con- trols of the unit. This cable must come out behind the wall plate and have a length of 30-40cm to reach the unit. When mounting the wall plate next to external piping, use the supplied brackets. Picture 2, 3.