Characteristics of the circuit card
1. Soft start
The moment of start is delayed with a TRIAC relay, giving a delay
of start-up current to the motor with about 1 second. The start-
up tension will in this way be much lower, which in turn means
that the wear on fuses, circuits and motor will be lower.
2. Low tension LED Auto-polarity *2
The green LED for the power cable, which is on the unit, will
always shine when there is current
3. Counter for hours worked *3
Through the use of EEPROM technology (program memory),
the card registers two types of timings that the user can easily
control, using a simple LED indicator that is placed on the shield
of the circuit board.
a. Short time b. Total time
4. Test of functions
After the power cable has been connected, the circuit board
performs a test of functions.
If everything is OK, the LED will flash rapidly for a few seconds
and then stop. Delay in shutdown. When turning off the vacuum
cleaner, a 2 second delay will be added in order to ensure that
the pipes and the hose are empty when the unit is turned off.
Reset / demo switch *6
Position Operation Result
Test/demo Press and release The board will perform a test
the switch of functions and will go though
within 5 seconds all steps in the previous table
(table 1)
Partial reset If the motor does not The system will reset the 15
run, press the switch hour counter to 0, the flashing
for 5 seconds the fashing LED (3) will continue
Total reset Press the swithch The system will reset the count-
for more than 30 er for total time to zero
seconds when the
motor is running
Performs the following actions:
7. Circuit breaker *7
The circuit board is
equipped with a circuit
breaker (Button marked
‘‘circuit breaker”.
To reset, press the
button.
*2 *3 *6 *7
how the pipe are laid out, and by noting where the suction is
still good, it should be possible to logically work out where the
stoppage is located.
5. Imagination? Many people, who just have had central vacuum
cleaners installed, are making an error in determining the suc-
tion, because the sound effects are absent.
Time of use LED colour Meaning Action
15 hours Green The vacuum cleaner Change/control dust
Change/control has been used bag and press con-
Slow flashing for 15 hours since firmation button for
last activation of the 5 seconds
confirmation button
0–399 hours Green < than 400 hrs of use ----
400–499 hours Orange > than 400 hrs of use Maintenance/inspect.
500–hours Red > than 500 hrs of use Have the engine serviced