ECU8*1B ECU8*2B ECU8*3B

Installation / Care / Use Manual

Refrigeration Package

INSTALLATION

1.Insure proper ventilation. In fully recessed drinking fountains be sure condenser faces louver panel and is within 1/2" (13 mm) of louver panel when panel is in place.

2.Water inlet is 3/8" (10 mm) O.D. unplated tube connector. Contractor to supply connections as required.

3.Connecting lines to be made of unplated copper. Thoroughly flush all lines to remove all foreign matter before connecting to cooler.

4.Connect cooler to building supply with a shut-off valve and install a 3/8" (10 mm) water line between the valve and cooler. Remove burrs from outside of water line. Insert water line into bulkhead union until it reaches a positive stop, approximately 3/4" (19 mm).

5.Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire the compressor directly to the power supply.

IMPORTANT! INSTALLER PLEASE NOTE:

The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal content of the water. This condition is avoidable by using the proper materials indicated below. Drain fittings which are provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.

START-UP

1.Open supply line valve.

2.Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected. A steady stream flow assures that all air is removed.

3.Rotate fan blade to assure proper clearance and free action.

4.Connect to proper electrical power.

TROUBLE SHOOTING & MAINTENANCE

Temperature Control: Factory-set for 50°F water (± 5°) under normal conditions. For colder water, adjust screw on item no. 5.

Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload protector.

Lubrication: Motors are lifetime lubricated.

Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4”.

WIRING DIAGRAM

 

 

 

 

OPERATION OF QUICK CONNECT FITTINGS

 

SIMPLY PUSH IN

TUBE IS SECURED

PUSH IN COLLET

 

TUBE TO ATTACH

IN POSITION

TO RELEASE TUBE

 

 

 

PUSHING TUBE IN BEFORE

 

 

 

PULLING IT OUT HELPS TO

 

 

 

RELEASE TUBE

 

 

 

 

97455C (Rev. G - 7/03)

Page 1
Image 1
Elkay ECU8*1B manual Installation, IMPORTANT! Installer Please Note, Start-Up, Trouble Shooting & Maintenance

ECU8*1B specifications

The Elkay ECU8*1B is a reliable water cooler designed to provide users with a consistent supply of clean, refreshing drinking water. This unit stands out in both residential and commercial settings due to its robust features and advanced technologies, making it an excellent choice for schools, offices, and public spaces.

One of the main features of the Elkay ECU8*1B is its dual-functionality, offering both chilled drinking water and a bottle-filling station. This caters to the growing demand for sustainability, as it encourages users to refill reusable bottles instead of purchasing single-use plastic. The filling station is designed to be user-friendly, with an integrated sensor that activates when a bottle is placed underneath, ensuring a hands-free experience.

The Elkay ECU8*1B is equipped with a high-efficiency refrigeration system that allows it to quickly chill water to ideal temperatures. This is particularly beneficial during peak usage times, ensuring that users always have access to cool water, even in high-demand environments. Additionally, the cooler features a user-replaceable water filter, which helps improve the taste and quality of drinking water by reducing contaminants.

In terms of durability and maintenance, the Elkay ECU8*1B is constructed with heavy-duty materials that withstand wear and tear, making it suitable for high-traffic areas. Its sleek stainless steel finish not only enhances its aesthetic appeal but also ensures long-lasting performance and ease of cleaning.

The unit's advanced technology includes a LED indicator that alerts users when the water filter requires replacement, simplifying maintenance and ensuring optimal performance. Furthermore, the ECU8*1B is designed to be energy-efficient, contributing to reduced operational costs over time.

Another notable characteristic is its ADA compliance, which makes it accessible to individuals with disabilities. The unit is designed at a height that allows easy access for all users, promoting inclusivity in public spaces.

In summary, the Elkay ECU8*1B combines functionality, sustainability, and user-friendly design in a single unit. With its dual capabilities, high-efficiency chilling system, durable construction, and user-centric features, it represents an excellent investment for any environment that prioritizes quality drinking water and user convenience.