CONFIGURATION MENU

Press the SYSTEM button until OFF is displayed, then press the and simultaneously

INSTALLER/CONFIGURATION MENU

 

Press

Displayed

Press or

 

Step

Button(s)

(Factory Default)

to select

Comments

1

System

MS 2

SS1, HP2, HP1

Selects Single stage, Multi-stage, or Heat Pump

 

 

 

 

 

 

(Single stage or 2-stage) System Configuration

2

System

FA

SL

Selects Fast or Slow Cycle Selection

 

 

 

 

 

 

 

3

System

CL

CL

Selects Compressor Lockout CL OFF or ON

 

 

(OFF)

(ON)

 

 

 

 

 

 

 

 

4

System

CDL

CDL

Selects Backlight Display

 

 

(ON)

(OFF)

 

 

 

 

 

 

 

 

5

System

FA

FA

Selects Fast Second Stage ON or OFF

 

 

(ON)

(OFF)

 

 

 

 

 

 

 

 

6

System

0 FLTR

50-1950(increments of 50)

Selects filter replacement run time

 

 

 

 

 

 

 

7

System

0°F

4 LO to 4 HI

Selects Temperature Display Adjustment 4 LO to 4 HI

 

 

(Room Temperature)

 

 

 

 

 

 

 

 

 

8

System

°F

°C

Selects temperature display or °C selection

 

 

 

 

 

 

 

9

System

AU On

OFF

Selects AUTO Mode ON or OFF

 

 

 

 

 

 

(Not available on earlier models)

 

 

 

 

 

 

 

10

System

LR

LR 62 to LR89

Selects Limited HEAT range

 

 

(90)

 

 

 

 

 

 

 

 

 

11

System

LR

LR 46 to LR 82

Selects Limited COOL range

 

 

(45)

 

 

 

 

 

 

 

 

 

12

System

CA

CA

Feature Not Available

 

 

(OFF)

(ON)

 

13

System

 

 

 

(ON)

Selects Keypad Lockout

 

 

 

 

 

(OFF)

 

 

14

System

0

001 to 999

Selects Keypad lockout combination number

 

 

 

 

 

 

Press System to set code

15

System

Returns to the OFF position

3)Select Compressor Lockout CL OFF or ON – Selecting CL ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling and heating cycles. This is intended to help protect the compressor from short cycling. Some newer compres- sors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs it will flash the setpoint for about five minutes.

4)Select Backlight Display – The display backlight improves display contrast in low lighting conditions. When the C terminal is powered, selecting backlight CdL ON will turn

the light on continuously. Select backlight OFF will keep the light on momentarily after any key is pressed. When the C terminal is not powered, this selection has no effect.

5)Select (Fast) Second Stage ON or OFF – In the run mode, if the setpoint temperature is manually raised by 3°F (2°C)

or more above the actual temperature with the , and the fast second stage feature is enabled, FA ON, the second stage will energize immediately. With FA OFF, second stage will not energize until the setpoint temperature is 1°F or more above actual temperature for more than ten min- utes.

6

Page 6
Image 6
Emerson 1F83-277 installation instructions INSTALLER/CONFIGURATION Menu

1F83-277 specifications

The Emerson 1F83-277 is a sophisticated programmable thermostat designed to bring efficiency and comfort to residential heating and cooling systems. This device stands out with its user-friendly interface and advanced features, making it an ideal choice for homeowners looking to modernize their HVAC control.

One of the main features of the 1F83-277 is its intuitive touchscreen display. The vibrant, easy-to-read screen allows users to effortlessly navigate through menus and settings. This interface is critical for accessing various functionalities, including temperature settings, scheduling programs, and energy-saving modes.

The thermostat is equipped with a five-day programming capability, enabling users to establish distinct heating and cooling schedules for weekdays and weekends. This level of customization allows for optimal energy management, as homeowners can set the temperature to match their daily routines. By adjusting the temperature according to specific usage patterns, users can significantly reduce energy consumption and lower utility bills.

Another notable feature is the inclusion of Smart Response Technology, which learns the heating and cooling needs of the home and adjusts the operation of the HVAC system accordingly. This intelligent adaptation ensures that the desired temperature is reached at the right time, enhancing overall comfort while maximizing energy efficiency.

The Emerson 1F83-277 supports multiple heating and cooling stages, accommodating various HVAC systems, including conventional, heat pump, and multi-stage configurations. This versatility makes it suitable for a wide range of residential settings, ensuring compatibility with most existing systems.

Additionally, the thermostat features a user-friendly setup process, allowing for quick installation and easy connectivity. It is compatible with various systems, including conventional, heat pumps, and gas or electric heating, which means it can fit seamlessly into any home environment.

Another key characteristic is its energy-saving features, such as an Eco mode that helps to minimize energy usage when the home is unoccupied. This is further augmented by the ability to track energy usage, enabling users to monitor their consumption patterns and make informed adjustments.

Overall, the Emerson 1F83-277 blends advanced technology with user-centric design, providing an efficient and comfortable heating and cooling solution for today's discerning homeowners.