PRECAUTIONS

PRECAUTIONS

DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.

!WARNING DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

1.Failure to turn off electric or main gas supply to clothes dryer could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion.

2.Do not use this control on circuits exceeding speci- fied voltage. Higher voltage will damage the control and may cause shock or fire hazard.

3.NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS–COULD CAUSE FIRE AND/OR EXPLOSION.

4.Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal injury and/or property damage, gas suffocation, fire, and/or explosion may result.

!CAUTION

1.Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, property damage, and/or per- sonal injury.

2.This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.).

INSTALLATION

1.

Before attempting to service dryer, unplug power cord,

 

turn off main gas supply and consult dryer manufactur-

 

er's instructions for accessing gas valve.

2.

Disconnect exhaust vent duct.

3.

Disconnect gas line from rear of dryer.

4.

Remove access panel from dryer. On some models this

 

involves removing the entire front panel.

5.

The gas valve/burner assembly should now be visible.

6.

The burner assembly consists of (see figure 1 & 2):

 

a. Gas inlet pipe.

 

b. Brass inlet fitting with union – some models may also

 

have a manual shut-off valve.

 

c. Gas valve.

 

d. Mounting bracket.

 

e. Burner orifice.

GINSTALLATION

H

F

E (not shown)

A

f.

Burner assembly with air shutter.

g.

Igniter.

h.

Radiant sensor – located on heat exchanger on

C

B

B

D

 

some models.

7.

Disconnect the wiring harness from gas valve and

 

igniter.

8.

Remove screw(s) fastening the mounting bracket to the

 

bottom of dryer.

9.

Burner assembly should now be free to slide out of the

 

front of dryer. Take care not to bump or jar igniter. It is

 

very fragile.

10.

Remove the gas inlet pipe by unscrewing the union.

11.

Remove screw(s) fastening the gas valve to the mount-

 

ing bracket and set them aside. They will be reused.