Emerson 36J, 36H manual Product Features and Specifications, 36C Series

Models: 36H 36J

1 28
Download 28 pages 16.22 Kb
Page 11
Image 11
►Product Features and Specifications

Product Features and Specifications

36C Series

Combination Gas Valve. The versatile 36C03 Series combination gas valves cover a wide range of applications. Designed for use with common ignition systems and standing pilots, it replaces hundreds of existing models in the field.

Features

 

• Standing Pilot

• Adjustable regulator(s)

• Single Stage

• Inlet/outlet screens

• Fast Opening

• Line interrupter

• Max. Capacity @

• Inlet/outlet pressure taps

1PD = 280,000 BTU/HR

• CSA approved

• Convertible – natural or LP gas

• Optional sidetaps

Specifications

 

Electrical Rating

0.23 Amps @ 24 VAC

Other Voltage

750 mV, 120 VAC

Operating Ambient Temperature

-40° to 175°F (-40° to 79°C)

Pressure Rating (max.)

1/2 PSI (14.0" W.C.)

Pilot Gas Connection

1/4" compression fitting

Pressure Tap

1/8" N.P.T.

4.200 SWING RADIUS

INLET 3/4" – 14 NPT (PLASTIC DUST PLUG INSTALLED)

0.875

1.125

VENT

.87536C Series.875

PRESS

PILOT

TAP

1.437

2.875

 

0.562

3.375

INLET PRESSURE TAP

 

 

1/8 - 27 N.P.T. THD.

 

 

OUTLET PRESSURE TAP

5.169

 

1/8 - 27 N.P.T. THD.

PILOT

 

 

PLUG

1.062

1.156

 

 

IN

OUT

LEFT & RIGHT

 

ALL DIMENSIONS

SIDE OUTLETS

 

IN INCHES

TAPPED 1/2" N.P.T.

 

 

& PLUGGED

INLET & OUTLET

SIDE OUTLETS

(1/2" PIPE PLUGS)

3/4 - 14 N.P.T. THD.

(PLUGGED)

 

1" PD Capacity

 

BTU/HR

Pipe Size

NAT GAS

LP GAS

(36 C)

0.64 Sp. Gr.

1.53 Sp. Gr.

 

 

(1000 BTU/HR)

(2500 BTU/HR)

1/2" x 3/4"

230,000

372,600

3/4" x 3/4"

280,000

453,600

 

 

 

 

Regulator

Valve

Adjustment

Range

Stages

 

 

 

 

 

 

Nat. Gas

LP Gas

Single

2.5" to 5.0"

7.5" to 12.0"

Stage

 

 

 

 

 

 

 

 

 

 

 

 

Regulator

 

Model

Typical

 

Type of

Pipe

Opening

Regulator

Adjustment

Side

Number

App.

Voltage

Gas

Size

Characteristics

Setting

Range

Taps

36C03-300

Standing Pilot

24 VAC

Nat./LP

1/2 x 3/4

Fast

3.5"

2.5"-5.0"

No

 

 

 

 

 

 

 

 

 

36C03-333

Standing Pilot

24 VAC

Nat./LP

1/2 x 3/4

Fast

3.5"

2.5"-5.0"

Yes

 

 

 

 

 

 

 

 

 

36C03-400

Standing Pilot

24 VAC

Nat./LP

3/4 x 3/4

Fast

3.5"

2.5"-5.0"

Yes

 

 

 

 

 

 

 

 

 

36C03-433

Standing Pilot

24 VAC

Nat./LP

3/4 x 3/4

Fast

3.5"

2.5"-5.0"

Yes

 

 

 

 

 

 

 

 

 

36C03U-333

Standing Pilot

750 mV

Nat./LP

1/2 x 3/4

Fast

3.5"

2.5"-5.0"

Yes

 

 

 

 

 

 

 

 

 

36C03U-433

Standing Pilot

750 mV

Nat./LP

3/4 x 3/4

Fast

3.5"

2.5"-5.0"

Yes

 

 

 

 

 

 

 

 

 

36C03A-410

Standing Pilot

120 VAC

Nat./LP

3/4 x 3/4

Fast

3.5"

2.5"-5.0"

No

Gas Valve Cross Reference 11

Page 11
Image 11
Emerson 36J, 36H manual Product Features and Specifications, 36C Series