36H Series

Product Features and Specifications

36H Series

Universal Replacement Electronic Ignition Gas Valve. The versatile 36H Series combination gas valves cover a wide range of applications. Designed for use with common ignition systems (HSI/DSI/Proven Pilot), it replaces hundreds of existing models in the field. The 36H Series is our highest capacity combination gas valve.

Features

 

• HSI/DSI/Proven Pilot

• Inlet/outlet screens

• Single Stage/Two-Stage

• Electric on-off switch

• Fast/Slow Opening

• Inlet/outlet pressure taps

• Convertible – natural or LP Gas

• CSA approved

• Adjustable regulator(s)

 

Specifications

 

Electrical Rating

0.41 amps (Single Stage)

 

0.54 amps (Two-Stage)

Voltage

24 VAC

Frequency

50/60 Hz

Operating Ambient Temperature

-40° to 175°F (-40°to 79°C)

Pressure Rating (max.)

1/2 PSI (14.0" W.C.)

INLET 3/4" – 14 NPT (PLASTIC DUST PLUG INSTALLED)

0.031

4.200 R SWING RADIUS

3.770

0.569

1.375

1.203

PROVEN

PILOT PLUG

CENTERLINE OF INLET & OUTLET

 

1.125

1.631

 

 

 

3.984 INLET TO OUTLET

 

1.375

 

 

 

 

 

 

3.259

 

 

 

 

 

 

INLET PRESSURE TAP

 

 

 

 

 

1/8" – 27 NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

1" PD Capacity

 

 

Regulator

 

 

BTU/HR

 

 

 

Pipe Size

 

Valve

Adjustment

 

(36 H)

NAT GAS

LP GAS

 

Stages

Range

 

 

0.64 Sp. Gr.

1.53 Sp. Gr.

 

 

 

 

 

 

(1000 BTU/HR)

(2500 BTU/HR)

 

 

Nat. Gas

LP Gas

 

 

 

 

 

Single

2.5" to 5.0"

5.0" to 12.0"

 

3/4" x 3/4"

300,000

486,000

 

Stage

 

 

 

 

 

1/2" x 3/4"

260,000

421,000

 

Two-

1.0" – 3.5" Low

4.0" – 9.5" Low

 

 

Stage

2.5" – 5.0" High

8.0" – 12.0" High

 

 

 

 

 

 

 

 

 

ALL DIMENSIONS IN INCHES

 

 

 

 

 

 

 

 

 

 

Convertible

Reducer

Inlet &

Model

 

Type of

Pipe

Opening

 

 

Proven

Standing

Intermittent

Nat./LP

Bushing

Outlet

Number

Voltage

Gas

Size

Characteristics

Stages

HSI/DSI

Pilot

Pilot

Pilot

Kit Included

Kit

Pressure Tap

36H32-304

24 VAC

Nat./LP

1/2 x 3/4

Fast

1

Yes

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36H32-423

24 VAC

Nat./LP

3/4 x 3/4

Fast

1

Yes

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36H33-412

24 VAC

Nat./LP

3/4 x 3/4

Slow

1

Yes

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36H64-463

24 VAC

Nat./LP

3/4 x 3/4

Fast

2

Yes

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36H65-401

24 VAC

Nat./LP

3/4 x 3/4

Slow

2

Yes

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

12Gas Valve Cross Reference