Emerson 5081T-FF/FI instruction sheet 140 125, 125 650 ±.015, Csa

Models: 5081T-FF/FI

1 24
Download 24 pages 36.88 Kb
Page 17
Image 17

This document contains information proprietary to Rosemount Analytical, and is not to be made available to those who may compete with Rosemount Analytical.

4X R .25

2X FULL R

.140

Ø .125

ROSEMOUNTRANALYTICAL

MODEL

SA R LR34186

5081-T-FI-69

ENCLOSURE 4

Exia ENTITY

INTRINSICALLY SAFE FOR

CLASS I, GRPS A, B, C & D

CLASS II, GRPS E, F & G

CLASS III

T3A Tamb = 70°C

HAZARDOUS AREA WHEN CONNECTED

PER DWG. 1400285

WARNING: COMPONENT SUBSTITUTION

MAY IMPAIR INTRINSIC SAFETY.

CLASS I, DIV. 2, GRPS A,B,C & D SUITABLE FOR

CLASS II, DIV. 2, GRPS E, F & G

T3A Tamb= 70°C

WARNING-EXPLOSION HAZARD-DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS.

WARNING-EXPLOSION HAZARD-SUBSTITU- TION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIV 2.

CLASS I, GRPS B,C & D

CLASS II, GRPS E, F & G

CLASS III

Tamb = 65°C MAX

Tamb ABOVE 60°C USE 75°C MINIMUM

RATED WIRING

SEAL REQUIRED TO BE INSTALLED

WITHIN 50 mm OF THE ENCLOSURE.

KEEP COVER TIGHT WHILE CIRCUITS

ARE LIVE.

9241516-01/A

.125

.650 ±.015

RELEASE DATE

ECO NO

REV

 

 

REVISIONS

 

 

 

LTR

ECO

DESCRIPTION

5-6-04

8925

A

.120 ±.015

2.56 ±.02

2.180 ±.005

BY DATE CHK

THIS DOCUMENT IS

CERTIFIED BY

CSA

REV A

 

REV

 

REV

 

REV

 

REV

 

REV

REVISIONS NOT PERMITTED

B 9241516-01

1.30 ±.02

W/O AGENCY APPROVAL

4 FINISH:SILKSCREEN BLACK EPOXY PAINT (BAKED).

3.ARTWORK IS SHEET 2 OF 2.

2.NO CHANGE WITHOUT CSA APPROVAL.

1MATERIAL: AISI 300 SERIES STAINLESS STEEL .015+/-.005 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 190.

NOTES: UNLESS OTHERWISE SPECIFIED

UNLESS OTHERWISE SPECIFIED

.XX

+

TOLERANCES

 

 

.030

+

1/2

.XXX

-

ANGLES

+

.010

-

 

 

-

 

 

DIMENSIONS ARE IN INCHES

REMOVE BURRS & SHARP EDGES .020 MAX

MACHINED FILLET RADII .020 MAX

NOMINAL SURFACE FINISH 125

MATERIAL

1

FINISH

4

ITEM

PART NO

 

 

DESCRIPTION

QTY

 

 

 

BILL OF MATERIAL

 

 

APPROVALS

DATE

Uniloc

 

Rosemount Analytical,

 

 

 

 

Irvine, CA 92606

 

 

 

 

 

 

Uniloc Division

 

 

 

 

 

 

2400 Barranca Pkwy

DRAWN

B. JOHNSON

5/3/04

TITLE

 

 

 

CHECKED

J. FLOCK

 

 

LABEL, I.S. CSA

5/6/04

 

 

PROJECT

J. FLOCK

5/6/04

 

 

5081-T-FI

 

ENGR APVD

 

DWG NO

REV

THIS DWG CREATED IN

 

SIZE

9241516-01

SOLID EDGE

 

 

 

A

 

 

B

 

 

 

 

 

 

SCALE 2:1

 

SHEET 1 OF 2

17

Page 17
Image 17
Emerson 5081T-FF/FI instruction sheet 140 125, 125 650 ±.015, Csa