Emerson 5081T-FF/FI instruction sheet Infrared Remote Controller Figure, I T N E X T

Models: 5081T-FF/FI

1 24
Download 24 pages 36.88 Kb
Page 3
Image 3

MODEL 5081T-FF/FI

TRANSMITTER DISPLAY DURING CALIBRATION AND PROGRAMMING (FIGURE 1)

1.Continuous display of conductivity, % concentration, or custom reading.

2.Units: µS/cm, mS/cm, ppm, %, or none.

3.Current menu appears here.

4.Submenus, prompts, and diagnostic readings appear hear.

5.Commands available in each submenu or at each prompt appear here.

6.Hold appears when the transmitter is in hold.

7.Fault appears when the transmitter detects a sensor or instrument fault.

INFRARED REMOTE CONTROLLER (FIGURE 2)

1.Pressing a menu key allows the user access to calibrate, program, or diagnostic menus.

2.Press ENTER to store data and settings. Press NEXT to move from one submenu to the next. Press EXIT to leave without storing changes.

3.Use the editing keys to scroll through lists of allowed settings or to change a numerical setting to the desired value.

4.Pressing HOLD puts the transmitter in hold. Pressing RESET causes the transmitter to abandon the present operation and return to the main display.

SPECIFICATIONS

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

2

7

F

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

U

#'" mS

 

 

 

 

 

H

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

6

D

 

 

 

 

3

 

 

 

 

 

 

 

CALIBRATE PROGRAM

DIAGNOSE

 

 

 

 

 

 

 

 

 

 

 

/ - [ 5 E S - U 1

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E X I T N E X T

E N T E R

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 1. TRANSMITTER DISPLAY DURING

CALIBRATION AND PROGRAMMING

The program display screen allows access to

calibration and programming menus.

4.

3.

1.2.

FIGURE 2. INFRARED REMOTE CONTROLLER

IRC - INFRARED REMOTE CONTROL

REMOTE CONTROL

LR 34186

Exia

 

INTRINSICALLY SAFE EQUIPMENT HAZARDOUS AREA LOCATIONS: CLASS I, DIV 1, GP A, B, C, D CLASS I, DIV 2, GP A, B, C, D

T3C Tamb = 40°C T3 Tamb = 80°C 1.5Vdc AAA BATTERIES EVEREADY E92/1212

DURACELL MN2400/PC2400

SUBSTITUTION OF

COMPONENTS MAY

IMPAIR INTRINSIC SAFETY

PN 23572-00

WARNING:

TO PREVENT IGNITION CHANGE BATTERIES IN A NONHAZARDOUS AREA ONLY

T4 Tamb = 40°C

YEAR

IS/I/1/A,B,C & D

 

NI/I/2/A,B,C & D

 

T3A Tamb = 80°C

 

Baseefa02ATEX0198

II1G EExia IIC T4 1180

1.5Vdc AAA BATTERIES EVEREADY E92/1212 DURACELL MN2400/PC2400

ROSEMOUNT ANALYTICAL 92606 USA

3

Page 3
Image 3
Emerson 5081T-FF/FI instruction sheet Infrared Remote Controller Figure, I T N E X T