Emerson 50A55 Integrated Furnace, Troubleshooting, Control Module, Guide, Chart, 4A4E, 4G YES

Models: 50A55

1 6
Download 6 pages 41.9 Kb
Page 5
Image 5
4A4E

INTEGRATED FURNACE

 

TROUBLESHOOTING

CONTROL MODULE

 

GUIDE

 

 

 

 

 

 

 

 

 

CHART 4

4A4E

Main Burner

Ignition Check.

Inducer ON.

Does ignitor

YES

warm up and

 

glow?

 

NO

4B

Turn power OFF to furnace.

Unplug ignitor from wire

harness. Connect voltmeter

across ignitor wiring harness leads from control. Energize system.

Does burner

YES

ignite?

 

NO

4F

Is gas

valve manual NO knob in ON position?

4G 4G YESYES

Turn manual knob to OFF position. Connect manometer to outlet pressure tap. Turn knob to ON position. Energize system.

Turn manual knob

to ON position.

Check operation.

Purge system of

air. Energize

system. Check

operation.

 

 

4C

4H

 

4I

 

 

 

Is outlet

 

 

 

 

 

 

Refer to service

Replace ignitor.

 

Is 120V

pressure

 

YES

YES

facts or installer’s

present at

detected after

Check operation.

 

 

guide for proper

 

ignitor leads?

ignitor warm-

 

 

 

 

pressure settings.

 

 

 

up time?

 

 

 

 

 

 

 

 

NO

NO

 

 

 

 

 

 

4J YES

Is manifold

pressure

adjusted to

required setting?

NO

4K

Is gas at source?

Adjust manifold

to required

NOpressure setting.

Check operation.

4D4L

YES

Replace broken or

 

Is 120V

YES

present at

defective wiring.

control terminals

 

Check operation.

 

IGN & IGN

 

 

NEUTRAL?

 

 

NO

Connect voltmeter

to gas valve

leads. Energize

system.

4M

Is 24V

detected

across gas

valve leads after

ignitor warm-

up time?

 

 

 

Restore gas

 

 

 

supply at source.

 

 

 

Check operation.

 

4N

 

 

 

Is 24V

 

 

 

present

 

Replace control

NO

across control

NO

 

MV terminals after

 

module. Check

 

ignitor warm-

 

operation.

 

up time?

 

 

 

YES

Replace control.

Replace gas

valve. Energize

Check operation.

system. Check

 

operation.

YES

Repair or

replace broken

leads to gas valve.

Check operation.

TECHNICAL HELP