Other Product Features Of The New Liebert GXT2 6 kVA Include:

Other Product Features Of The New Liebert GXT2 6 kVA Include:

Flexibility:

Rack/tower configuration — A single part number installs in either configuration.

Automatic frequency detection — The Liebert GXT2 6 kVA detects and matches line input frequencies of either 60 or 50 Hz.

Additional runtime with 2U battery cabinets — UPS cabinet includes rear panel plug-and-play connections for optional additional battery cabinets.

IntelliSlotcommunications port — Utilizes Liebert IntelliSlot Web Card to provide SNMP and web-based monitoring and control your UPS.

Includes Windows-based configuration program — Allows various operating parameters to be adjusted and tests to be scheduled.

Built-in serial communications for use with Liebert MultiLinkAutomated Shutdown Software — Allows you to monitor communication between the UPS and a server, and ensures

a graceful unattended shutdown.

Built-in closure signals — Provides notification to monitoring systems of operating conditions including: on battery, low battery, battery mode shutdown and any mode shutdown.

Emergency Power Off (EPO) — Terminal connections for a normally open or normally closed emergency power off switch.

Reliability

Wider Input Voltage Window Minimizes Battery Use — The Liebert GXT2 6 kVA features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery, extending system availability for when battery back-up is truly needed.

Internal automatic and manual bypass — Assures continuity of power to critical loads during system maintenance or in case of internal fault.

Self-diagnostics — Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

User-replaceable hot-swappable internal batteries — Provide five minutes of runtime at full load.

Low Total Cost Of Ownership

Standard two-year warranty

Uses less rack space leaving more room for network equipment.

Batteries are shielded from heat generating electronic components, enhancing battery life.

Battery cutoff voltage automatically adjusts based on load, extending battery life by preventing over-discharge of batteries.

Patented Feature Enhances Reliability

The Liebert GXT2 6 kVA includes a patented output neutral bonding feature designed to comply with UL 1778, which requires that input conductors of the UPS (including neutral) be disconnected from the input source when the UPS is in battery mode. The Liebert GXT2 6 kVA features a patented circuit that maintains the UPS output neutral to ground bond in all modes of operation, thereby eliminating any voltage induced on the UPS output neutral connection.