D E C 2012

DANIELTM MODEL 788DVC DIGITAL CONTROL VALVES

Table 3-2. Maximum Working Pressure

Pressure/Temperature

ASTM A352 LCC WCB

150# ANSI/-20 to 100/F

285 psig WP

150# ANSI/150/F

272 psig WP

150# ANSI/250/F

245 psig WP

150# ANSI/450/F

185 psig WP

300# ANSI/-20 to 100/F

740 psig WP

300# ANSI/150/F

707 psig WP

300# ANSI/250/F

665 psig WP

300# ANSI/450/F

334 psig WP

600# ANSI/-20 to 100/F

1480 psig WP

600# ANSI/150/F

1415 psig WP

600# ANSI/250/F

1332 psig WP

600# ANSI/450/F

667 psig WP

P/N 16/-29 to 66/C

16 bar WP

P/N 16/121/C

15.8 bar WP

P/N 16/232/C

13.7 psig WP

P/N 25/-29 to 66/C

25 bar WP

P/N 25/121/C

24.7 bar WP

P/N 25/232/C

21.6 psig WP

P/N 40/-29 to 66/C

40 bar WP

P/N 40/121/C

39.6 bar WP

P/N 40/232/C

34.4 bar WP

P/N 63/-29 to 66/C

63 bar WP

P/N 63/121/C

62.4 bar WP

P/N 63/232/C

54.3 bar WP

P/N 100/-29 to 66/C

100 bar WP

P/N 100/121/C

99 bar WP

P/N 100/232/C

86.2 bar WP

3-6

SPECIFICATIONS

Page 22
Image 22
Emerson 788 DVC manual Astm A352 LCC WCB