DANIELTM MODEL 788DVC DIGITAL CONTROL VALVES

D E C 2012

6.Lift off the cylinder head by taking out the socket screws.

7.Remove and inspect all O-rings for nicks, cuts and wear.

Figure 5-1. Using the Piston to Insert the Seat Ring into the 150/300 lb. Cylinder

Table 5-l. Typical Opening/Closing Speed

 

Typical

Recommended Low Flow Set-point

Typical

Typical

Typical

Typical

Line

Dead

 

 

 

 

Opening

Opening

Closing

Closing

Size

Time

 

Turbine

PD Meter

Speed

Time

Speed

Time

Inches

Setting

 

Adjust-

(Shut-off

Adjust-

(Full

 

 

 

 

 

(Seconds)

 

 

 

 

ment

to Full

ment

Open to

 

 

gpm

K-factor

gpm

K-factor

(Turns

Open)

(Turns

Shut-off)

 

 

 

 

 

 

Open)

Seconds

Open)

Seconds

2-3

0.015

100

50

100

100

0.25

5.0

0.75

2.0

4

0.015

150

25

150

25

0.25

5.0

0.75

2.0

6

0.030

150

25

150

25

0.75

5.0

1.25

2.0

8

0.030

150

25

150

25

0.75

5.0

1.25

2.0

DISASSEMBLY AND REASSEMBLY

5-3

Page 33
Image 33
Emerson 788 DVC manual Recommended Low Flow Set-point