While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2006 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
of their respective owners.
® Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-22070 (R10/06) Printed in USA
Business-Critical Continuity, Emerson Network
Power and the Emerson Network Power logo
are trademarks and service marks of Emerson
Electric Co. ©2006 Emerson Electric Co.

Emerson Network Power.com

Emerson Network Power.

The global leader in enabling

Business-Critical Continuity.

AC Power

Connectivity

DC Power

Embedded Computing

Embedded Power

Monitoring

Outside Plant

Power Switching & Controls

Precision Cooling

Racks & Integrated Cabinets

Services

Surge Protection

Liebert Corporation

1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX

liebert.com

Technical Support

800 288 6169 Toll-Free
607 724 2484 Phone
607 722 8713 Fax
How To Order
Liebert AccuGuide®
Voltage configuration:
Wye (Y), Delta (D), Split Phase (S)
Modes of protection:
111-All modes for Y system
110-line to line, line to ground
101-line to neutral, neutral to ground
Liebert AccuGuide lengths:
5 feet 8 feet 10 feet 12 feet 15 feet 20 feet
Pigtail gauge:
No. 6 AWG No. 8 AWG No. 10 AWG
Note: 5 feet of pigtail length will be provided on each
side of the Liebert AccuGuide assembly. Please specify
pigtail gauge (conduit nipple to SPD connection/conduit
nipple to power source connection).
How to construct an AccuGuide
(ACG) model # Code
1. Liebert AccuGuide ACG
2. Voltage configuration Y
3. Mode of protection 111
4. Liebert AccuGuide length: 8 feet 08
5. Pigtail gauge: No. 8 AWG 08
Sample model #: ACGY1110808
Required conduit size: 1 ⁄2" to 2"

Liebert AccuGuide Coax Construction

Ordering Information:
Liebert AccuGuide cable assemblies are available
in several standard lengths for any service
configuration with up to seven modes of
protection. The conductor gauge is configured
to accommodate the system.

Primary &

Secondary

Insulation

Jacket

Outer Braid

Inner Braid

Conductor

General Specifications

Voltage (VAC) 0 to 600
Operating frequency (Hz) 0 to 400
Altitude (m) 18,000 feet
Operating temperature (°C) -40 to +90
Operating humidity (%) 0 to 95 (non-condensing)
Flame resistance VW-1
DC resistance (mΩ/ft/mode) ≤ 1.3
Warranty 5-years
Safety agency approval UL Listed Wire Assembly Kit
Patent number 5,384,429