BP7357 CF180 BRIDGETON 9/19/07 11:21 AM Page 10

 

STANDARD ON-OFF WALL

 

 

 

SWITCH OR OPTIONAL SW101

 

 

WALL CONTROL

BLACK

 

TO

BLACK

 

(HOT)

 

BLACK

120-

 

 

 

VOLT

 

 

WHITE

SUPPLY

WHITE

 

 

 

WHITE

 

 

 

 

 

 

GROUND

RED

 

 

 

 

TWO-CONDUCTOR

BLUE

WHITE

 

 

CABLE (WITH

 

 

 

 

 

GROUND)

 

 

 

 

 

GREEN WIRE (GROUND)

BLACK

 

 

 

BLUE

 

 

 

FROM HANGER BALL AND

 

WHITE

 

Figure 13

HANGER BRACKET

 

 

 

 

HANGER BALL

3. Push the wires and connectors up into

!

WARNING

 

the outlet box while inserting the receiv-

 

 

 

 

 

er fully into the hanger bracket. Position

To avoid possible fire or shock, make

 

the antenna wire on top of the receiver.

sure that the electrical wires are

4.

Screw the two 1-1/4” threaded studs

completely inside the outlet box and

not pinched

between the ceiling

 

(supplied) into the tapped holes in the

 

cover and the ceiling.

 

hanger bracket (Figure 12).

 

 

 

 

5.

Lift the ceiling cover up to the threaded

7. Screw three 60-watt (maximum) cande-

 

studs and turn until the studs protrude

labra base flame bulbs into the light

 

through the holes in the ceiling cover

fitter sockets (Figure 15).

 

(Figure 14).

 

 

 

 

6. Secure the

ceiling cover in place by

 

 

 

 

sliding lockwashers (supplied) over the

 

 

 

 

threaded studs and installing the two

 

 

LIGHT

 

knurled knobs (supplied). (Figure 14).

 

 

 

Tighten the

knurled knobs securely

60-WATT

 

FITTER

 

 

 

 

until the ceiling cover fits snugly against

 

 

 

CANDELABRA

 

 

 

the ceiling.

 

BASE BULB (3)

 

ARM

 

 

 

 

RING

 

 

CEILING

CHANNEL

 

 

 

COVER

SCREWS (6)

 

 

 

 

 

 

LOWER

 

 

 

 

 

GLASS

 

LOWER RING

 

 

 

Figure 15

 

 

 

 

 

ASSEMBLY

LOCKWASHER

THREADED

8. Unscrew the six ring screws from the

(2)

 

STUD (2)

lower ring assembly (Figure 15).

KNURLED

 

Position the lower glass in the lower

KNOB (2)

 

ring assembly so that the six channels

Figure 14

 

in the glass align with the six arms of

the lower ring assembly.

10

U.L. Model No.: CF180

Page 10