Emerson CF180AP00 owner manual How to Wire Your Ceiling Fan

Models: CF180AP00

1 16
Download 16 pages 41.36 Kb
Page 9
Image 9
How to Wire

BP7357 CF180 BRIDGETON 9/19/07 11:21 AM Page 9

How to Wire

Your Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experi- ence, have your fan installed by a licensed electrician.

!WARNING

Turning off wall switch is not suffi- cient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accor- dance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

CAUTION: To reduce the risk of electri- cal shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver.

Manual backgroundManual background 1. Position the supply wires to the left side of the outlet box (Figure 12); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 12.

NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire

is visible at the wire connectors, except for the ground wire.

Manual backgroundManual background 2. Refer to Figure 12 and 13 and connect the receiver wires to the supply wires and the fan motor wires as follows:

a.Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation).

b.Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire.

c.Securely connect the supply black wire (hot) wire to the receiver black (AC IN

L)wire.

d.Securely connect the fan motor white wire to the receiver white (TO MOTOR

N)wire.

e.Securely connect the fan motor black wire to the receiver red (TO MOTOR L) wire.

f.Securely connect the fan motor blue wire to the receiver blue (FOR LIGHT) wire.

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire con- nectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

SUPPLY WHITE WIRE

(NEUTRAL)

 

AC

 

I

 

N

N

SUPPLY BLACK

 

WIRE (HOT)

 

GROUND WIRE

 

GREEN GROUND

WIRE FROM

HANGER BALL

ANTENNA

GREEN GROUND

WIRE FROM

HANGER BRACKET

1-1/4" THREADED

Figure 12 STUD (2)

RECEIVER WHITE

 

 

 

 

 

WIRE

RECEIVER

 

 

 

 

BLACK WIRE

 

 

 

 

RECEIVER RED WIRE

 

 

 

 

 

 

RECEIVER BLUE

 

 

 

 

 

 

WIRE

 

 

 

 

 

MOTOR

L

AC IN L

MOTOR

N

 

 

 

 

LIGHT

 

 

 

 

 

TO

 

 

 

TO

 

FOR

 

 

 

FAN

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

WIRE

 

 

 

 

 

 

FAN BLUE WIRE

 

 

 

 

 

 

FAN WHITE WIRE

RECEIVER WHITE WIRE

 

9

 

U.L. Model No.: CF180

Page 9